APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21772 Issued:2011-05-06
Revised:2011-05-06
Style 21772 Jacketed cable

Rating80 deg C, 300 Vac, Cable flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationPVC, 25 mils minimum average thickness, 22 mils minimum thickness at any point. SRPVC, 10 mils minimum average thickness, 9 mils minimum thickness at any and point. HDPE, 10 mils minimum average thickness, 9 mils minimum thickness at any point.
AssemblyTwo jacketed cables laid parallel and bonded together or joined by an interconnecting web. Cable 1 consists of two or more conductors employing PVC insulation and overall PVC jacket. Cable 2 consists of 1 or more conductors employing HDPE insulation and 1 or more conductors employing SRPVC insulation, shield and overall PVC jacket.
ShieldOptional.
CoveringOptional.
JacketPVC.
Dia of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.
 