APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21776 Issued:2011-06-29
Revised:New
Style 21776 Multiple conductor with extruded insulation

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor32 AWG - 10 AWG, solid or stranded.
InsulationTPES, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
AssemblyTwo insulated conductors laid parallel.
ShieldRequired.
CoveringPolyester tape (heat sealed). Covering thickness 0.6 mil minimum average, 0.4 mil minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.