This Style Page is no longer being updated. It is for historic reference only. Please visit: Search - Appliance Wiring Material - Company - Product iQ for the latest Style Page information 
Subj.758 Section 2 Page 21776 Issued:2011-06-29
Revised:New
Style 21776 Multiple conductor with extruded insulation

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor32 AWG - 10 AWG, solid or stranded.
InsulationTPES, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
AssemblyTwo insulated conductors laid parallel.
ShieldRequired.
CoveringPolyester tape (heat sealed). Covering thickness 0.6 mil minimum average, 0.4 mil minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2026