Style 21777 Multiple Conductor Cable Using Non-Integral Jacket.

Rating80 deg C,30 V, Horizontal Flame, VW-1 flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationLabeled or complying with this manufacturer's Procedure.
Inner ShieldRequired Inner Shield - Metal Tape provided over each pair of conductors.
BinderOptional - Polyester tape may be provided over the inner shield of each conductor pair.
ShieldRequired - Metal tape provided over the complete conductor core.
ShieldRequired - Metal braid provided under the overall jacket.
AssemblyTwo or more individually insulated conductors cabled together. Each conductor pair shall employ an inner shield and an optional binder polyester tape over the inner shield. The pairs shall be cabled together with a metal tape shield over the complete conductor core. An overall metall braid shield shall be provided over the metal tape and under the overall jacket.
JacketTPU with min average thickness 30 mils, minimum thickness at any point 24 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.