APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2178 Issued:1959-05-01
Revised:2012-07-09
Style 2178 Multiconductor with Extruded Insulation and Extruded Non-integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
ConductorThree (30 No. 18 AWG comprised of 16 strands of No. 30 AWG and Nine (9) No. 24 AWG comprised of 7 strands of No. 32 AWG, tinned copper.
InsulationExtruded PVC, 15 mils min average, 14 mils minimum at any point, nominal 15 mil wall thickness in white, black, and brown colors for the No. 18 AWG conductors, and in white purple, blue, green, yellow, orange, red, brown and black colors for the No. 24 AWG conductors.
AssemblyTwelve conductors, three (3) No. 18 AWG insulated conductors are twisted together to form a core. The nine (9) conductors No. 24 AWG insulated conductors are twisted around the core. A cotton wrap serving shall be applied over the assembly.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs Television Remote Control Cable.

UL and the UL Logo are trademarks of UL LLC © 2024