Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | Three (30 No. 18 AWG comprised of 16 strands of No. 30 AWG and Nine (9) No. 24 AWG comprised of 7 strands of No. 32 AWG, tinned copper. |
|
Insulation | Extruded PVC, 15 mils min average, 14 mils minimum at any point, nominal 15 mil wall thickness in white, black, and brown colors for the No. 18 AWG conductors, and in white purple, blue, green, yellow, orange, red, brown and black colors for the No. 24 AWG conductors. |
|
Assembly | Twelve conductors, three (3) No. 18 AWG insulated conductors are twisted together to form a core. The nine (9) conductors No. 24 AWG insulated conductors are twisted around the core. A cotton wrap serving shall be applied over the assembly. |
|
Jacket | PVC, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | As Television Remote Control Cable. |
|