Rating | 90 deg C,300 V, Horizontal flame; Optional - Oil Res 60 deg C. |
|
Conductor | 50 AWG - 10 AWG, solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together; or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional inner layer. |
|
Jacket | Extruded TPU with 30 mils minimum average thickness, 24 mils minimum thickness at any point. See Facing Page for Compound. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|