APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21787 Issued:2011-10-07
Revised:New
Style 21787 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 30 Vac, VW-1 flame, Cable flame.
Conductor40 AWG - 8 AWG, solid or stranded.
InsulationExtruded PTFE, 4 mils minimum average thickness, 3 mils minimum thickness at any point.
AssemblyTwo or more insulated conductors with optional inner shield and overall jacket.
ShieldOptional.
JacketExtruded PVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.400 inch or less24 mils20 mils
0.401-0.700 inch30 mils24 mils
0.701-1.500 inch45 mils36 mils
1.501-2.500 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024