APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21789 Issued:2011-10-26
Revised:2011-11-10
Style 21789 Multiconductor cable With Extruded Non-integral Jacket

Rating90 deg C, 300 Vac, Horizontal flame, Cable flame.
Conductor38 AWG - 4 AWG, solid or stranded.
InsulationExtruded FEP, 9 mils minimum average thickness, 8 mils minimum at any point.
CoveringOptionl, extruded XLPE, 22 mils minimum average thickness, 17 mils minimum at any point.
AssemblyThe cable consists of two insulated conductors, may be laid parallel to form flat, oval or round cables
ShieldOptional, Aluminium-mylar tape, with tinned copper drain wires.
JacketExtruded PVC
Dia. of Cable Under Jacket in Inchhmils min averagemils min at any point
0.700 or less3124
0.701 - 1.0004536
1.001 - 1.5006048
1.501 - 2.5008064
# Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.