APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21795 Issued:2011-11-30
Revised:New
Style 21795 Multiple-conductor cable with extruded non-integral jacket.

Rating105 deg C, 150 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more insulated conductors.
CoveringOptional.
ShieldOptional.
JacketExtruded PVC.
Diameter of core assembly under jacket in inchMinimum average thickness milsMinimum thickness at any point mils
0.700 or less1714
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
# See Facing Page for compound designation where the cable with diamater of core assembly under jacket, 0.700 inch or less.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024