APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2180 Issued:1959-05-01
Revised:2012-07-31
Style 2180 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 16 AWG, stranded
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
AssemblyTwo conductors, same as type SJT.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn the internal wiring and support of Cord-suspended electric lighting fixtures at temperatures not exceeding 105 deg C.