APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2181 Issued:1959-05-01
Revised:2011-10-28
Style 2181 Multiple-conductor cable with extruded non-integral jacket

Rating60 deg C, 300 Vac, FT-2 Flame.
Conductor18 AWG - 10 AWG, stranded, consists of 0.0049 in - 0.010 inch conductor strands (18 - 14 AWG) or 0.0049 in - 0.016 inch conductor strands (12 -10 AWG).
InsulationExtruded PVC.
Conductor sizeMinimum average thicknessMinimum thickness at any point
18-12 AWG30 mils27 mils
10 AWG45 mils40 mils
AssemblySix insulated conductors, same as type SJT.
JacketExtruded PVC.
Conductor sizeMinimum average thicknessMinimum thickness at any point
18-14 AWG30 mils24 mils
12 AWG45 mils36 mils
10 AWG60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring used in couches and hospital beds.

UL and the UL Logo are trademarks of UL LLC © 2024