APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21815 Issued:2012-02-29
Revised:New
Style 21815 Multi-conductor cable with extruded non-integral jacket

Rating80 deg C,300 V, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs or groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG size. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
JacketExtruded TPU, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.