			| Rating | 90 deg C, 30 Vac, Horizontal Flame. | 
			|  | 
			| Insulation | Labeled or complies with manufacturer's AWM Procedure. | 
			|  | 
			| Assembly | Two or more singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. Lay not specified. Barrier layer and/or binders, fillers optional. Manufacturer shall maintain a complete description of each assembly. Overall Cable may be either straight or coiled in the form of a helix. | 
			|  | 
			| Shield | Optional. | 
			|  | 
			| Jacket | Extruded TPE | 
			|  | diameter of cable under jacket | mils min average | mils min at any point | 
			|  | 1.500 inches or less | 45 | 36 | 
			|  | 1.501-2.500 inches | 60 | 48 | 
			|  | 
			| Standard | Appliance Wiring Material UL 758. | 
			|  | 
			| Marking | General. | 
			|  | 
			| Use | Internal Wiring. | 
			|  |