APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21832 Issued:2012-04-10
Revised:2012-12-11
Style 21832 Multiconductor Cable With Extruded Non-Integral Jacket.

Rating80 deg C, 150 Vac, Cable Flame.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyTwo or more singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. Lay not specified. Barrier layer and/or binders, fillers optional. Manufacturer shall maintain a complete description of each assembly. Overall Cable may be either straight or coiled in the form of a helix.
ShieldOptional.
JacketExtruded TPE
diameter of cable under jacketmils min averagemils min at any point
1.000 inches or less4536
1.001-1.500 inches6048
1.501-2.500 inches8064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection.

UL and the UL Logo are trademarks of UL LLC © 2024