APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21840 Issued:2012-04-17
Revised:New
Style 21840 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 1000 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's Procedure.
AssemblyTwo or more singles, twisted pairs of groups or twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional-Inner.
JacketExtruded TPE
dia of cable under jacket(in)*Minimum Average Thickness (mils)Minimum Thickness at any point (mils)
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
2.501-4.00011088
4.001 or larger140112
*Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.