Rating | 80 deg C, 30 Vac, Horizontal flame. |
|
Insulation | Labeled or complying with AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. Each insulated conductor pair shall be shielded. |
|
Inner Shield | Inner metal tape shall be provided over each conductor pair. |
|
Binder | Optional binder tape may be provided over the conductor core. |
|
Covering | Optional - Inner extruded PVC covering may be provided. |
|
Outer Shield | An outer metal tape shall be provided. |
|
Braid | An outer metal braid shall be provided under the overall jacket. |
|
Jacket | Extruded PVC, 25 mils minimum average thickness, 20 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring in Class 2 circuits only. |
|