APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21844 Issued:2012-05-04
Revised:2012-05-07
Style 21844 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. Each insulated conductor pair shall be shielded.
Inner ShieldInner metal tape shall be provided over each conductor pair.
Binder TapeOptional binder tape may be provided over the conductor core.
CoveringOptional - Inner extruded PVC covering may be provided.
Outer ShieldAn outer metal tape shall be provided.
BraidAn outer metal braid shall be provided under the overall jacket.
JacketExtruded PVC, 25 mils minimum average thickness, 20 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring in Class 2 Circuits only.