Style 21852 Multi-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together; or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional
ShieldRequired metal tape or metal braid shall be provided under the overall jacket.
JacketExtruded mPPE-PE
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.400 inch or less24 mils20 mils
0.401-0.700 inch30 mils24 mils
0.701-1.500 inch45 mils36 mils
1.501-2.500 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.