APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21855 Issued:2012-05-31
Revised:New
Style 21855 Multi-conductor cable using non-integral jacket

Rating80 deg C, 600 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together; or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional.
ShieldRequired metal tape or metal braid shall be provided under the overall jacket.
JacketExtruded mPPE-PE
Dia of Cable under jacketMin averageMinimum at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024