APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21859 Issued:2012-05-31
Revised:New
Style 21859 Multi-conductor cable using non-integral jacket

Rating80 deg C, 600 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together; or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
JacketExtruded mPPE-PE, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.