APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21864 Issued:2012-07-06
Revised:2019-11-07
Style 21864 Multiple-conductor cable using non-integral jacket.

Rating200 deg C, 30 V ac, Cable flame.
Insulated ConductorLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more insulated conductors, twisted pairs, groups of twisted conductors or singles or groups of singles laid parallel to form flat, oval or round cable. A barrier layer and/or fillers are optional.
ShieldOptional.
CoveringOptional.
JacketExtruded Thermoplastic Fluoropolymer. See facing page for compound designation and mixture ratio. ;
dia under jacket in inches
0.350 or less10 mils minimum average thickness8 mils minimum thickness at any point
0.351 - 0.500 dia13 avg10 min
0.501 - 0.700 dia15 avg12 min
0.701 - 1.500 dia20 avg16 min
1.501 - 2.500 dia30 avg24 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2025