Rating | 150 deg C, 30 V ac, Cable flame. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more insulated conductors, twisted pairs, groups of twisted conductors or singles or groups of singles laid parallel to form flat, oval or round cable. A barrier layer and/or fillers are optional. |
|
Shield | Optional. |
|
Covering | Optional. |
|
Jacket | Extruded Thermoplastic Fluoropolymer. See facing page for compound designation and mixture ratio.; |
| dia under jacket in inches |
| 0.350 or less | 10 mils minimum average thickness | 8 mils minimum thickness at any point |
| 0.351 - 0.500 dia | 13 avg | 10 min |
| 0.501 - 0.700 dia | 15 avg | 12 min |
| 0.701 - 1.500 dia | 20 avg | 16 min |
| 1.501 - 2.500 dia | 30 avg | 24 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External wiring. |
|