APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21875 Issued:2012-09-28
Revised:New
Style 21875 Mult-conductor cable with non-integral jacket

Rating75 deg C,30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM File.
AssemblyConsists of 2 or more Pods laid flat and parallel and joind by interconnecting webs. Each Pod consists of 2 or more labeled insulated conductors or groups of conductors cabled together or 2 or more fiber optic members cabled together, with optional fillers, optional shields, optional binder tapes, optional inner jackets, and overall dual layered jacket of TPU and foamed PTFE.
ShieldOptional.
Inner JacketOptional.
JacketExtruded dual layer jacket conisting of inner TPU layer with minimum average thickness 12 mils, minimum thickness at any point 10 mils adhered to an outer layer of foamed PTFE with minimum average thickness 3 mils, minimum thickness at any point 2 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.