APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21886 Issued:2013-03-04
Revised:New
Style 21886 Multiple-conductor Cable using Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Insulated Conductor50 AWG - 22 AWG, Labelled or complying with Manufacture's AWM Procedure.
AssemblyTwo or more insulated singles or cables laid parallel or two or more conductors, twisted pairs or groups of twisted conductors twisted together. May include fillers or barrier layer. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketExtruded PVC, 5 mils minimum average thickness, 4 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment in Class 2 systems only.

UL and the UL Logo are trademarks of UL LLC © 2024