APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21899 Issued:2013-06-07
Revised:New
Style 21899 Multiple-conductor cable using non-integral jacket.

Rating150 deg C,600 Vac, Cable flame; Oil Resistant 60 deg C (Optional).
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Inner ShieldOptional
CoveringOptional
Outer ShieldOptional
JacketExtruded FEP.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.350 inch or less10 mils8 mils
0.351-0.500 inch13 mils10 mils
0.501-0.700 inch15 mils12 mils
0.701-1.500 inch20 mils16 mils
1.501-2.500 inch30 mils24 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring Interconnection of Electronic Equipment or Appliances.

UL and the UL Logo are trademarks of UL LLC © 2024