APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21901 Issued:2013-06-07
Revised:New
Style 21901 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 600 Vac, Horizontal flame; Oil Resistant 60 deg C (Optional).
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Inner ShieldOptional
CoveringOptional
Outer ShieldOptional
JacketExtruded TPU, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring Interconnection of Electronic Equipment or Appliances.

UL and the UL Logo are trademarks of UL LLC © 2025