APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21906 Issued:2013-06-06
Revised:New
Style 21906 Multiple-Conductor Using Non-Integral Jacket

Rating105 deg C, 600 Vac, Cable flame; Oil Res 60 C (optional); Moisture Res 75 C (optional); Sunlight Res (optional).
ConductorSolid or stranded
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
JacketExtruded TPE
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.00 - 0.700 inch30 mils24 mils
0.701 - 1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment or appliances