APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21908 Issued:2013-07-03
Revised:New
Style 21908 Multiple conductor cable with extruded non-integral jacket

Rating105 deg C, 300 Vac, Cable flame; Moisture Res 75 ; 720hr Sunlight Res .
InsulationLabeled or complies with manufacturer's AWM Procedure having a minimum rating of 75 deg C wet.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use mixed sizes of insulated singles.
ShieldOptional - metal shield may be provided over one or more of the insulated conductors or applied over the complete conductor core.
JacketPVC - Recognized Component QMTT2 720 Hour Sunlight Resistant PVC Jacket Compound
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 dia4536
1.001-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024