APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21915 Issued:2013-07-24
Revised:New
Style 21915 Multiple Conductor Cable using Non-Integral Extruded Jacket

Rating105 deg C, 600 Vac, Horizontal Flame.
InsulationLabeled or complyling with the manufacturer's AWM procedure.
AssemblyTwo or more insulated single conductors.
ShieldOptional.
CoveringOptional.
JacketExtruded mPPE
diameter of round assembly under jacket in inches*mils min. averagemils min at any point
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
* Equivalent diameter of flat assembly = 1.1284 x (TW)^1/2 in which T is the thickness of the assembly under the jacket, and W is the width of the assembly under the jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024