| Rating | 85 deg C,100 Vac Cable flame; Sunlight Res (optional). |
|
| Conductor | 30 AWG - 4/0 AWG, solid or stranded. |
|
| Insulation | Extruded FRPE, 14 mils minimum average thickness, 12 mils minimum thickness at any point |
|
| Covering | Optional |
|
| Shield | Optional |
|
| Assembly | Two or more insulated singles twisted together. Lay not specified. Fillers, Shields, Braids and/or barrier layers description of each assembly. |
|
| Jacket | Extruded FRPE. |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.400 inch or less | 24 mils | 20 mils |
| 0.401-0.700 inch | 30 mils | 24 mils |
| 0.701-1.500 inch | 45 mils | 36 mils |
| 1.501-2.500 inch | 60 mils | 48 mils |
| |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring and External Wiring |
|