Rating | 80 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 40 AWG - 20 AWG, solid or stranded. |
|
Insulation | Extruded HDPE, 4 mils minimum average thickness, 3 mils minimum thickness at any point before and after separation. |
|
Assembly | 6 - 66C insulated conductors laid parallel by thermal bonding with 4 - 34 conductive HDPE shield members which are extruded over each metal strength member. |
|
Shield | AL part of AL/PET tape and extruded conductive HDPE members with drain wires. |
|
Covering | AL/PET tape, 1.0 mil minimum thickness bonded with EVA adhesive, 0.1 mils minimum thickness, wrapped with minimum 5% overlap. Overlap portion is covered by PET tape, 0.5 mils minimum thickness and 160 mils minimum width, bonded with Polyester adhesive, 0.1 mils minimum thickness. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Class 2 circuit. |
|