APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21933 Issued:2013-10-28
Revised:New
Style 21933 Flat Ribbon Cable with extruded Integral Insulation

Rating80 deg C,300 Vac Horizontal flame.
Conductor32 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 12 mils minimum average thickness, 11 mils minimum thickness at any point.
AssemblyTwo to twelve conductors laid parallel and in one plane. May use same or mixed AWG size. Minimum average and minimum at any point of insulation thickness after ripping shall be 12 mils and 11 mils, respectively. This forms a flat cable with a single row of conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024