APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21937 Issued:2014-01-26
Revised:New
Style 21937 Multiple-conductor Cable Using Non-Integral Jacket

Rating90 deg C,300 Vac, Cable flame.
Conductor32 AWG - 16 AWG, solid or stranded.
InsulationExtruded ETFE, 12 mils minimum average thickness, 10 mils minimum thickness at any point, rating 150 degree C and 300Vac
AssemblyTwo or more insulated conductors laid parallel or twisted together to form cable core.
ShieldPoly Aluminum Foil Tape 100 % coverage with Tin plated Copper drain wire or Copper braid with 65% minimum coverage
JacketExtruded PVC
Diameter of core assembly under jacket*Minimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
*equivalent diameter = 1.1284 X (TW)1/2 if cable is flat or oval assembly. _T is the thickness of the assembly under the jacket and W is the width of the assembly under the jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.