Rating | 90 deg C,300 Vac, Cable flame. |
|
Conductor | 32 AWG - 16 AWG, solid or stranded. |
|
Insulation | Extruded ETFE, 12 mils minimum average thickness, 10 mils minimum thickness at any point, rating 150 degree C and 300Vac |
|
Assembly | Two or more insulated conductors laid parallel or twisted together to form cable core.
|
|
Shield | Poly Aluminum Foil Tape 100 % coverage with Tin plated Copper drain wire or Copper braid with 65% minimum coverage
|
|
Jacket | Extruded PVC |
| Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| 1.501-2.500 inch | 80 mils | 64 mils |
| *equivalent diameter = 1.1284 X (TW)1/2 if cable is flat or oval assembly. _T is the thickness of the assembly under the jacket and W is the width of the assembly under the jacket. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment. |
|