APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21939 Issued:2014-02-05
Revised:New
Style 21939 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 1000 Vac, Cable flame.
Conductor32 AWG - 12 AWG, solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded TPU/PVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch60 mils48 mils
1.001-1.501 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024