APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2194 Issued:1959-05-01
Revised:2012-03-09
Style 2194 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 300 Vac, FT2 flame.
Conductor22 AWG solid or stranded round, tinned or bare.
InsulationExtruded PVC, 15 mils minimum average thickness, 14 mils minimum thickness at any point.
AssemblyThree conductors, same as type SVT, with a shield applied over one conductor as a wrap or braid.
ShieldNo. 36-30 AWG tinned copper strands applied as a wrap or braid.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs remote control cable for Tape Recorders.