APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21944 Issued:2014-02-27
Revised:New
Style 21944 Multiple Conductor Cable using Non-Integral Jacket

Rating80 deg C, 600 Vac, Cable flame.
InsulationLabeled Style 11538
AssemblyConsists of two or more conductors, twisted pairs, or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. M ay use same or mixed AWG size.
SeparatorOptional
CoveringOptional
ShieldOptional
JacketExtruded TPU
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less35 mils28 mils
0.701 - 1.000 inch60 mils48 mils
1.001 - 1.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.