APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21945 Issued:2014-03-06
Revised:New
Style 21945 Multiple conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 10 AWG, solid or stranded.
InsulationFRPE, 9 mils minimum average thickness, 8 mils minimum thickness at any point.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
JacketExtruded FRPE;
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.00 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024