Rating | 90 deg C,300 Vac Cable flame. |
|
Conductor | Resistance Wire. 48-10 AWG. Copper alloy, Nickel chromium, or other suitable resistance wire element wound around the insulation; size and number of turns dependent upon wattage demand. |
|
Insulation | Extruded PVC, 30 mils minimum average thickness, 27 mils thicness minimum at any point. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Extruded PVC, 15mils minimum average thickness, 13 mils thickness minimum at any point. |
|
Jacket | Extruded PVC, 30mils minimum average thickness, 27 mils thickness minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|