APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21949 Issued:2014-03-19
Revised:New
Style 21949 Multiple conductor cable using non-integral jacket

Rating90 deg C,300 Vac Cable flame.
ConductorResistance Wire. 48-10 AWG. Copper alloy, Nickel chromium, or other suitable resistance wire element wound around the insulation; size and number of turns dependent upon wattage demand.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils thicness minimum at any point.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringExtruded PVC, 15mils minimum average thickness, 13 mils thickness minimum at any point.
JacketExtruded PVC, 30mils minimum average thickness, 27 mils thickness minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024