APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2195 Issued:1959-05-01
Revised:2011-09-23
Style 2195 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor18 AWG stranded, 4.9 - 6.5 mils strands diameter. Same as Type SVT.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyThree conductors, same as Type SVT.
ShieldOptional. Wrap or braid, consisting of No. 36-30 AWG tinned copper strands may be applied over one conductor.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs Remote Control Cable for Automatic Slide Projectors at temperatures not exceeding 60 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024