APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21954 Issued:2014-05-07
Revised:2019-10-11
Style 21954 Multiple-conductor Cable Using Non-integral Jacket

Rating125 deg C, 1000 Vac, Cable flame.
Conductor50 AWG - 2000 kcmil, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. May use same or mixed AWG size.
ShieldOptional
CoveringOptional
JacketExtruded TPE
Diameter under the jacket in inchesmin averageminimum at any point
0.700 or less30 mils24 mils
0.701-1.000 dia45 mils36 mils
1.001-1.500 dia60 mils48 mils
1.501-2.500 dia80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring.

UL and the UL Logo are trademarks of UL LLC © 2024