APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21959 Issued:2014-08-28
Revised:2014-10-29
Style 21959 Multiple-Conductor Cable Using Non-Integral Jacket

Rating90 deg C, 600 Vac, Horizontal Flame; Oil Res 60 (optional); Sunlight Res (optional).
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional
CoveringOptional
JacketExtruded TPU
Diameter of Cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 or less inch30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.