APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21963 Issued:2014-09-29
Revised:New
Style 21963 Multiple conductor cable using extruded insulation and extruded non-integral jacket

Rating90 deg C,300 Vac.
Conductor22 AWG - 16 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two 22 AWG and two 16 AWG insulated conductors, twisted together with Kevlar strength members, covered by cellular TPE with outer skin.
JacketExtruded Cellular TPE (non-Styrenic) 220 mils minimum average thickness, minimum thickness at any point 176 mils; with non-separable TPE outer skin, 30 mils minimum average thickness, minimum thickness at any point 24 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing.

UL and the UL Logo are trademarks of UL LLC © 2024