APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21964 Issued:2014-09-30
Revised:2014-11-24
Style 21964 Multiple conductor cable using extruded insulation and extruded non-integral jacket

Rating60 deg C, 60 Vac; 60 deg C Wet (required).
Conductor44 AWG - 10 AWG, solid or stranded.
InsulationRecognized Component QMTT2 Extruded PVC insulation suitable for Types THWN or THWN-2, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
AssemblyConsists of two or more conductors, twisted pairs, or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. A barrier layer and/or fillers are optional.
JacketExtruded TPE, 40 mils minimum average thickness, 32 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing.

UL and the UL Logo are trademarks of UL LLC © 2024