APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21970 Issued:2015-02-04
Revised:2015-03-09
Style 21970 Multiple conductor with extruded non-integral jacket

Rating60 deg C, 300 Vac, Cable Flame, VW-1 flame.
Conductor24 AWG - 16 AWG, stranded.
InsulationLabeled or complies with manufacturer's procedure.
AssemblyFour or more singles and optical fiber members cabled around the strength member. Optical fiber core - Construction not specified. Strength Member - Stranded steel with minimum 12 mils of polyethylene or PVC covering. The length of lay of twisted singles is not specified. Fillers and/or barrier layer optional and their materials are not specified. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketExtruded PVC
Dia. of Cable Under JacketMin averageMin at any point
0.275 inch or less42 mils33 mils
0.276-0.425 inch50 mils40 mils
0.425-0.700 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal, External and Interconnecting Wiring; Where the acceptability is determined by UL LLC, may be for use with Professional Video and Audio Equipment