APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21971 Issued:2015-02-04
Revised:2015-08-18
Style 21971 Multiple conductor cable with extruded non-integral jacket

Rating80 deg C, 300 Vac, Cable Flame, VW-1 flame.
Conductor24 AWG - 16 AWG, stranded.
InsulationLabeled or complies with manufacturer's procedure.
AssemblyFour or more singles and optical fiber members cabled around the strength member. Optical fiber core - Construction not specified. Strength Member - Stranded steel with minimum 12 mils of polyethylene or PVC covering. The length of lay of twisted singles is not specified. Fillers and/or barrier layer optional and their materials are not specified. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
Inner CoveringOptional. Extruded PVC, thickness not specified.
JacketExtruded PVC
Dia. of Cable Under JacketMin averageMin at any point
0.275 inch or less42 mils33 mils
0.276-0.425 inch50 mils40 mils
0.425-0.700 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal, External and Interconnecting Wiring; Where the acceptability is determined by UL LLC, may be for use with Professional Video and Audio Equipment

UL and the UL Logo are trademarks of UL LLC © 2024