APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21974 Issued:2015-02-27
Revised:New
Style 21974 Multiconductor cable with extruded non-integral jacket.

Rating150 deg C, 300 Vac, Horizontal flame, Cable flame, Optional Sunlight Resistant.
Conductor38 AWG - 1/0 AWG, solid or stranded.
InsulationExtruded FEP, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
JacketExtruded FEP.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.350 inch or less12 mils9 mils
0.351-0.500 inch13 mils10 mils
0.501-0.700 inch15 mils12 mils
0.701-1.500 inch20 mils16 mils
1.501-2.500 inch30 mils24 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring. In addition, the tag may also indicate the following: Suitable for Sunlight Resistant or Sun-Res.

UL and the UL Logo are trademarks of UL LLC © 2024