APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21996 Issued:2015-04-27
Revised:2022-08-25
Style 21996 Multiple-conductor Cable using Non-integral jacket

Rating105 deg C, -40 deg C, 300 Vac, Horizontal Flame Test, Cable Flame Test; 60 deg C wet (required); Sunlight Res (required).
Conductor50 AWG min., solid or stranded.
InsulationExtruded PVC, 16 mils minimum average thickness, 14 mils minimum thickness at any point. Any Recognized Component (QMTT2) PVC Compound acceptable for use on Types THWN or THWN-2.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional.
ShieldOptional.
JacketExtruded PVC, Any Recognized Component (QMTT2) 720 hours sunlight Resistance PVC Compound.
Diameter of core assembly under jacket(inch)Minimum average thickness (mils)Minimum thickness at any point (mils)
0 - 0.7003024
0.701 - 1.0004536
1.001 - 1.5006548
1.501 - 2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or External Use Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024