Rating | 60 deg C, 9000 Vdc, Cable flame. |
|
Conductor | 32 AWG - 10 AWG, solid or stranded. |
|
Insulation | Extruded XLPE, 45 mils minimum average thickness, 41 mils minimum thickness at any point. |
|
Assembly | Two or more singles or groups of twisted singles twisted together. Lay not specified. Barrier layers, tape(s) and/or fillers optional. |
|
Shield | Optional - metal tape(s) and/or metal braid(s). |
|
Covering | Optional. |
|
Jacket | Extruded PVC |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 1.500 inches or less | 68 mils | 54 mils |
| 1.501 -2.500 inches | 80 mils | 64 mils |
| 2.501-4.500 inches | 110 mils | 88 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|