APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22006 Issued:2015-05-18
Revised:New
Style 22006 Multi-Conductor cable with extruded non-integral jacket

Rating105 deg C, 9000 Vdc, Horizontal flame.
Conductor32 AWG - 10 AWG, solid or stranded.
InsulationExtruded XLPE, 45 mils minimum average thickness, 41 mils minimum thickness at any point.
AssemblyTwo or more singles or groups of twisted singles twisted together. Lay not specified. Barrier layers, tape(s) and/or fillers optional.
ShieldOptional-metal tape(s) and/or metal braid(s).
CoveringOptional.
JacketExtruded PVC, 68 mils minimum average thickness, 54 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024