APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22012 Issued:2015-07-13
Revised:2015-07-27
Style 22012 Multiple Conductor Cable with Extruded Non-integral Jacket.

Rating80 deg C,30 Vac Cable flame.
Conductor40 AWG - 12 AWG, solid or stranded.
InsulationExreuded PVC (7 mils minimum average thickness, 6 mils minimum thickness at any point)
AssemblyTwo or more insulated conductors with optional covering, optional shield and overall jacket. Core may be either flat or round. Barrier layer, fillers, optical fibers optional.
ShieldOptional.
JacketExtruded TPU (15 mils minimum average thickness, 13 mils minimum thickness at any point)
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or External Wiring in Class 2 circuits only.

UL and the UL Logo are trademarks of UL LLC © 2024