APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22013 Issued:2015-08-12
Revised:New
Style 22013 Bonded or Laminated Flat Ribbon Cable

Rating60 deg C, 80 deg C, 30 Vac, 150 Vac, VW-1 flame.
Conductor36 AWG - 10 AWG, solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure, The minimum voltage and temperature ratings of the singles shall be the rating of the overall cable.
AssemblyTwo to thirty insulated singles, twisted pair triads or parallel pairs laid parallel in one plane, intermittently or continuously bonded together or bonded to the PVC covering to form a flat ribbon type cable or twisted to form a round cable. Parallel pairs may be shielded. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable.
Inner CoveringOptional, extruded PVC or one or two sheets of PVC or polyester/PVC laminated film, each sheet is 2 mil min at any point, laminated over the cable assembly. Film covering may be perforated. Hole diameter and pattern is not specified.
ShieldOptional
Outer CoveringOptional, PVC, 5 - 10 mils; Or PTFE, 2 -80 mils; Or one or two layers of 1 mils polyester film with polyester adhesive.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial Internal Wiring with VW-1 Flame Rating, Only.

UL and the UL Logo are trademarks of UL LLC © 2025